  next up previous contents index  Xplor-NIH home Documentation

Next: Translation Function for Molecule Up: Generalized Molecular Replacement Previous: PC-Refinement of the Highest


Analysis of the PC-refinement

In the present case, the analysis of the filtering procedure is straightforward: a single peak is produced, which corresponds to the orientation of one of the molecules. The second molecule is not found in this particular run, since its orientation was not among the first 240 peaks of the rotation function. This shows a problem with the $PC$-refinement strategy: if no solution is found, one cannot be sure that there is no solution. A “direct" rotation search (see Section 19.7) may help in these cases. Another aspect of the result of the filtering procedure is that sometimes several $PC$-refinements converge on the same solution. The Rotman statement provides a facility to measure the “distance" or metric between two rotation matrices by removing crystallographic redundancies. Suppose one wants to know the distance between two orientations of the search model ($\theta_1$=80.477, $\theta_2$=85.000, $\theta_3$=24.806) and ($\theta_1$=261.392, $\theta_2$=90.000, $\theta_3$= 336.243) taking into account the crystallographic symmetry. Using the Rotman statement
xrefin
  a=44.144 b=164.69 c=70.17 alpha=90. beta=108.50 gamma=90.
  symmetry ( x, y, z  )
  symmetry ( -x, y+1/2, -z )
end
rotman
   euler=(80.477  85.000  24.806)
   swap
   euler=( 261.392  90.000 336.243)
   dist
end
one finds that the difference between these two orientations is about 5$^{\circ}$, due to the crystallographic symmetry.


next up previous contents index
Next: Translation Function for Molecule Up: Generalized Molecular Replacement Previous: PC-Refinement of the Highest   Contents   Index
Xplor-NIH 2025-03-21
  • Privacy Policy
  • Freedom of Information Act
  • Accessibility
  • Disclaimers
  • Copyright
  • Vulnerability Disclosure Policy
  • U.S. Department of Health and Human Services
  • National Institutes of Health