![]() ![]() ![]() ![]() ![]() | Xplor-NIH home Documentation |
Next: Requirements Up: Rigid-Body Minimization Previous: Rigid-Body Minimization
Syntax
- MINImize RIGId
- {
minimize-rigid-statement
} END is invoked from the main level of X-PLOR.
minimize-rigid-statement
:==
-
- DROP=
real
- designates the expected initial drop in energy (default: 1).
- GROUp=
selection
- selects atoms that will be forming a rigid group. Multiple specification of GROUps will define multiple rigid groups. The group selections have to be disjoint (default: one group consisting of all nonfixed atoms). The default is overwritten as soon as a GROUp statement is issued.
- NPRInt=
integer
- is the frequency of the energy printout (default: 1).
- NSTEp=
integer
- is the maximum number of minimization cycles (default: 50).
- TOLErance=
real
- stops minimization if the norm of
the gradient of the energy function
is smaller than the specified number (default: 0.01).
- DROP=
Subsections
Xplor-NIH 2024-09-13